JXF10A~400A
This product is a modular distribution box with advanced technology and performance introduced from ABB.
This product is equipped with a miniature circuit breaker to prevent line overload and short circuit, and reliably ensure the safety of lines and equipment. The structure of the busbar on the distribution board has been reasonably improved. The distribution board meets the requirements of modularization. The MCB series distribution box is mainly used in various places such as civil buildings, factories, shopping malls, schools, and government offices. It can also be used as a protection for overload, short circuit, leakage, and undervoltage in frequent line conversion and low-power power lines.
The installation method includes open installation and concealed installation, and the gourd hole wall hanging type can be used. It is installed with screws and has a mounting plate inside.
Download Brochure
◎ Product model meaning
1. Distribution Box Model: JXF Series
2. Distribution Box Codes:
- MI - Lighting Box
- ACM - Lighting Box
- ACP - Lighting Box
- SDB - Lighting Box
- Gk - Lighting Control Box
- Yk - Remote Control Box
- Stock - Time Control Box
- QA - Accident Switch Box
- QD - Accident Switch Box
- TA - Accident Input Box
- TD - Accident Input Box
- J - Inspection Box
- B - Transformer Box
- J - Emergency Power Box
- N - Inverter Box
- K - Switch Box
- C - Socket Box
- A - Push Button Box
- MK - Enclosed Switch Box
- MC - Enclosed Socket Box
3. Installation Method:
- R - Recessed
- No R - Surface-mounted, or general enclosure for indoor and outdoor, recessed
4. Configuration Code (based on actual situation)
◎ Product mix
The power distribution box (cabinet) is closed, the shell is generally welded with cold rolled steel plate, and can also be assembled with profiles, the left and right side walls of the box welding electrical original installation column, the whole piece can also be installed according to the plate, using standardized design and production. The same products can be interchangeable, surface spray, fixed flat. It can also be operated in full serial number, the above can be used for voltage, ammeter indicator light measurement and measurement and button operation; open the door can detect the equipment. Hand can also be used double bottom plate, so that personnel can not directly contact the conductive body, to ensure safety.
Model | outline dimension | Installation Size (Installation) | baseboard | ||||
tall | wide | deep | H | B | tall | wide | |
JXF-2520/14 | 250 | 200 | 140 | 290 | 240 | 170 | 158 |
JXF-3025/14 | 300 | 250 | 140 | 340 | 290 | 220 | 208 |
JXF-3025/18 | 300 | 250 | 180 | 340 | 290 | 220 | 208 |
JXF-3030/14 | 300 | 300 | 140 | 340 | 340 | 220 | 258 |
JXF-3030/18 | 300 | 300 | 180 | 340 | 340 | 220 | 258 |
JXF-4030/14 | 400 | 300 | 140 | 440 | 340 | 320 | 258 |
JXF-4030/20 | 400 | 300 | 200 | 440 | 340 | 320 | 258 |
JXF-5040/14 | 500 | 400 | 140 | 540 | 440 | 420 | 358 |
JXF-5040/20 | 500 | 400 | 200 | 540 | 440 | 420 | 358 |
JXF-5040/23 | 500 | 400 | 230 | 540 | 440 | 420 | 358 |
JXF-6040/14 | 600 | 400 | 140 | 640 | 440 | 520 | 358 |
JXF-6040/20 | 600 | 400 | 200 | 640 | 440 | 520 | 358 |
JXF-6040/23 | 600 | 400 | 230 | 640 | 440 | 520 | 358 |
JXF-6050/14 | 600 | 500 | 240 | 640 | 540 | 520 | 458 |
JXF-6050/20 | 600 | 500 | 200 | 640 | 540 | 520 | 458 |
JXF-6050/23 | 600 | 500 | 230 | 640 | 540 | 520 | 458 |
JXF-7050/16 | 700 | 500 | 160 | 740 | 540 | 620 | 458 |
JXF-7050/20 | 700 | 500 | 200 | 740 | 540 | 620 | 458 |
JXF-7050/23 | 700 | 500 | 230 | 740 | 540 | 620 | 558 |
JXF-8060/20 | 800 | 600 | 200 | 840 | 640 | 720 | 558 |
JXF-8060/23 | 800 | 600 | 230 | 840 | 640 | 720 | 558 |
JXF-8060/25 | 800 | 600 | 250 | 840 | 640 | 720 | 758 |
JXF-10080/20 | 1000 | 800 | 200 | 1040 | 840 | 920 | 758 |
JXF-10080/23 | 1000 | 800 | 230 | 1040 | 840 | 920 | 758 |
JXF-10080/26 | 1000 | 800 | 260 | 1040 | 840 | 920 | 758 |
JXF-120050/40 | 1000 | 800 | 260 | 1040 | 840 | 920 |